Reference | 58.10.4075 |
Date | 5/6/2010 |
Location | Middle East |
Scope | 1- Supply of # 24 clamp-on type ultrasonic gas flowmeter for moc degassing stations ultrasonic gas flowmeter clamp-on type FLUXUS G800 or equivalent with ip66 enclosuer for permanent installation and all accessories for measuring the output natural gas for the degasing stations. All electronic components a flame proof enclosure. Terminals and terminal boxes have the type of protection. The instrument work according to the transit- time principle the transducers are mounted on to the piped (clamp - on technique) - Basic design data: fluid: natural gas flow rate: min: 2.5 mmscf/d, max: 20 mmscf/d meter type: clamp - on technique ultrasonic flowmeter lines sizes: 6" - 14" pipes wall thichness: min: 5.5mm, max: 14mm max. operating press: 10 kg/cm² Operating temp: min: 0 °c max: 55 ° c - Technical data : Measuring principle: transit time difference flow velocity: ( 0.01 to35 ) m/s Repeatability: 0.15 % or better Accuracy: 0.1 % or better Power supply: (100 - 240) vac, (12 - 36) vdc Display: 2 x 16 characters Operating temp: - 5ú c to 55ú c - Measuring function: Quantities measurement: volume and mass flow rate, flow velocity. Totalizers: volume, mass. Current measuring range: (0/4 to 20) ma Operating language: multi Main language: English - Flow transducer: Suitable set of ultrasonic flow wave transducer, normal temp range for Atex zone 1 connection system is with junction box and suitable extension cable. Design temp: -10 °c - 120 °c (orbiter). - Junction box: Technical type: JBO 1S4E3M or equiv Installation: wall mounting or 2" pipe mounting Housing: stainless steel 316 Gasket: silicone Degree of protection: ip67 acc to en60529 - Meters calibration: Each ultrasonic flowmeter is to be individually calibrated at the manufacture's facility on a petroleum product, with one of methods recommended by API standards. The meters are to be calibrated on at least five points over the catalog flow range with three calibration runs. 2- Supply of # 12 UPS system suitable to deliver power: Accrue on the inverter. The UPS should be operating for two hours at least. Input power: 220 vac 50 hz 3- Supply of # 3000 mtr control cables: Individually screened control cable10c x 1.5 mm² pvc insulated over shield with alum/pst foil along (6 drum * 500 mtr) over all pvc, armored wire. 4- Supply of Spare part: Two years of operation spare parts for the flowmeter, transducers, junction box, ups, extension cable and all items. |
Bid Bond | 1% of submitted prices |
Bond Validity | 120 days |
Offer Validity | 120 days |
Documents Price | USD 500 |