It is required to supply electronic flow meters to measure the consumption fuel (Gases & Liquids) by boilers, furnaces, generators and flairs.

It must be done by Ex-d flow meters offered the Net and thermally compensated volumes to (15, 20) C and a pressure of 1.01325 bar.

The total quantity are 18 (eighteen) Flow meters.


# 4 flow meters with the following Specification:

Product: (HN & LN)
Pipe size: 1.5" vertical installation Flow direction towards up
Flow rate range(F.R.R.): (0.1 to 1.5) m/hr
Op.Temp: (30 to 85) C
Op. pressure: (9 10) bar
Differential pressure: 0.5 bar
Sp. Gr.: (0.65 to 0.75)
Used for units (1, 2, 3) Fueling (liquid phase) to the furnaces
With strainer and air release


# 4 flow meters with the following Specification:

Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2s)
Pipe size: 4" horizontal installation
F.R.R.: (100 to 500) Nm/hr
Op.Temp : ( 30 to 65 ) C
Op. pressure: (0.1 to 2.5) bar
Differential pressure: 0.05 bar
Density: 3.4 Kg/m
Used for units ( 1 , 2 , 3 ) Fuel ( gas phase ) to the flair


# 4 flow meters with the following Specification:

Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2S)
Pipe size: 4" horizontal installation
F.R.R.: (30 to 350) Nm/hr
Op.Temp: (30 to 65) C
Op. pressure: (0.1 to 2.5) bar
Differential pressure: 0.05 bar
Density: 3.4 Kg/m
Used for units (1, 2, 3) Fuel (gas phase) to the furnaces
These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall.

# 3 flow meters with the following Specification:

Product: Gas Oil
Pipe size: 1.5 "horizontal installation
F.R.R.: (2 to 20) m/hr
Op.Temp: (10 to 65) C
Op. pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For units (1, 3) Fuel (liquid phase) to the Boiler & Generator.
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
These flow meters should be blind head type (equipped with a separate display) mounted on
The wall (remote)
With strainer and air release

# 1 flow meters with the following Specification:

Product: Gas Oil
Pipe size: 1.5" horizontal installation
F.R.R.: (1 to 10) m/hr
Op.Temp: (10 to 65) C
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
Op. pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For unit (2) Fuel (liquid phase) to the Boiler
These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall. With strainer and air release

# 2 flow meters with the following Specification:

Product: Gas Oil
F.R.R.: (1 to 10) m/hr
Op.Tem: (10 to 65) C
Water & Sediment V%: 0.05
ASH Max% 0.01 weight
P. pressure: (2 to 3) bar
Differential pressure: 0.3 bar
For unit (2) Fuel (liquid) to the Generator
With strainer and air release

Bidding Information

Bid Bond 1% from submitted prices
Documents Price ID 100000
Flowmeters
Related Prooducts: Flowmeters General Magnetic Flowmeter Mass Flowmeter Open Channel Ultrasonic Flowmeter Orifice Plate Flowmeter Turbine Flowmeter Ultrasonic Flowmeter Variable Area Flowmeter Venturi Tube Water Meter
Related Tenders: General Mass Flowmeter Open Channel Ultrasonic Flowmeter Turbine Flowmeter Ultrasonic Flowmeter Water Meter

Related Articles

For Buyers
For Suppliers
Gulf Oil and Gas
Copyright 2021 Universal Solutions All rights reserved. - Terms of Service - Privacy Policy.